Equipment must be purchased through Persolvent to ensure compatibility with our card present integrations.
Key features:
- Part of the TETRA line of Ingenico devices
- Ethernet connection
- Countertop terminal that requires a power source
- Supports swipe, EMV, and contactless payments
- Cloud based software that pushes updates to the terminal
Key functions:
- Press the green O button to turn on the device
- Press the yellow < button to clear
- Press the red X key to cancel and go back to the previous screen
- Press the yellow < button and the .,#* button at the same time to reboot the device
- Enter 0000 to see the Terminal Status
- Enter 0001 for the Admin Menu
Settings configuration:
This device establishes a persistent outbound connection to USAePay. It does not need to be on the same network as the point of sale. If you have firewall rules on your network, you will need to whitelist eft://direct.paymentengine.io:9021 to establish a connection.
- Enter 0001 for the Admin screen
- Press 2 for Ethernet parameters
- 1-IP configuration The static IP assigned to the device
- 2-Connection Type 2-Client
- 3-Bind interface 0.0.0.0
- 4-Ethernet Status Active
- 5-Server IP address direct.paymentengine.io
- 6-Port 9021
- 7-SSL Mode None
- 8-URL eft://direct.paymentengine.io:9021
- 9-Ping URL direct.paymentengine.io
We recommend not making any changes to the settings menu unless instructed to do so by our Support Team. The device is already configured to work with USAePay.
If you are instructed to make a change, follow these steps:
- Enter 0001 for the Admin screen
- Press 2 for Ethernet parameters
- Select the setting you need to change by entering the number or tapping the screen
- Make the necessary change
- Hit the red X button
- You will be asked if you want to Save and Reboot
- Select 1-Yes to continue or select 2-No to cancel the change
- When the device reboots, go back to the Admin menu to make sure the change was made